Thermo Scientific Model 146i Multi-Gas Calibrator
The Thermo Scientific Model 146i Multi-Gas Calibrator supplies precise levels of ozone, carbon monoxide, non-methane hydrocarbons, sulfur dioxide, nitric oxide, and nitrogen dioxide or other gases that a user may require. The gas levels are used to calibrate instruments that perform zero, precision and level 1 span checks, audits and multipoint measurements. The design of the Thermo Scientific Model 146i calibrator meets or exceeds all published U.S. EPA requirements for multipoint calibration, audit, Level 1 and 2 span and precision checks. Options include Gas Phase Titration, UV Photometer, and Permeation Oven. The mass flow controller, ozone generator, permeation tube oven, power supply, and solenoid valves are integrated into a single microprocessor-controlled unit. This permits easy to use, menu-driven software and a consistent set of operation screens for all calibration procedures. Additionally, the microprocessor can make many of the necessary calculations, thereby freeing the operator from having to make the calculations in
the field or laboratory. If desired, the Model 146i calibrator can be operated remotely by a data logger to perform multipoint calibrations.
Features:
Ethernet connectivity for effi cient remote access
Enhanced user interface with one button programming and large display screen
Flash memory for increased data storage and user downloadable software
Enhanced electronics design optimizes product commonality
Gas Phase Titration for generation of O3 and NO2
Flow Measurement Accuracy | +/- 2% of reading or 1% of full scale whichever is less (20 to 100% full-scale) |
Linearity of Mass Flow Measurement | +/- 0.5% of full scale |
Repeatability of Mass Flow Measurement | +/- 2% of reading or 1% of full scale whichever is less (20 to 100% full-scale) |
Flow Range of Dilution Air | 0-10 SLPM. Optional ranges: 0-5/0-20 SLPM |
Flow Range of Cylinder Gases | 0-100SCCM. Optional ranges: 0-50/0-200 SCCM |
Zero Air Requirements | 10 SLPM @ 30 PSI Optional ranges: 20 SLPM @ 30 PSI |
Calibration Gas Input Ports | 3 optional 6 |
Dilutent Gas Input Ports | 1 |
Response Time | 99% of target (at manifold) within 60 seconds |
Ozone Generator Option | Maximum output: 1 ppm @ 6 SLPM. Minimum output: 10 ppb @ 6 SLPM |
Photometer System | Full Scale Range: 100 ppb to 5 ppm user selectable. Linearity: 1% of Full Scale. |
Precision: | 1 ppb. Response Time: 180 Seconds to 95% of Target. Minimum Detectable Limit 3 ppb. |
Test Channel Analog | 6 @ +/- 100 mv 1510 volts (user selectable) |
Digital Control Outputs | 10 relay and 8 24vdc solenoid |
Digital Control Inputs | 16 |
Temperature Range | 0°- 45° C |
Weight | 51 lbs (58 lbs for 220-240 VAC) |
Dimensions | 16.75 W x 8.62 H x 23 D |
Power | 100 VAC 50/60Hz 115 VAC 50/60Hz 220-240 VAC 50/60Hz 275 watts (with all options) |