Thermo 450I
Utilizing pulsed fluorescence technology the Model 450i H2S and SO2 analyzer operates on the principle that H2S can be converted to SO2. As the SO2 molecules absorb ultraviolet (UV) light and become excited at one wavelength, the molecules then decay to a lower energy state emitting UV light at a different wavelength. The pulsing of the U.V. source lamp serves to increase the optical intensity whereby a greater U.V. energy throughput and lower detectable SO2 concentration are realized. Reflective bandpass filters, as compared to commonly used transmission filters, are less subject to photochemical degradation and are more selective in wavelength isolation. This results in both increased detection specificity and long term stability.This state-of-the-art gas analyzer also offers features such as an ethernet port as well as flash memory for increased data storage. Ethernet connectivity provides efficient remote access, allowing the user to download measurement information directly from the instrument without having to be on-site.
Features:
Pulsed excitation and intensity stabilization
Reflective bandpass filters
Stable lone-life UV source
Superior zero stability
Temperature stabilization reaction chamber
Preset Ranges | 0-0.05 0.1 0.2 0.5 1 2 5 and 10 ppm |
Extended Ranges | 0-0.5 1 2 5 10 20 50 and 100 ppm |
Custom Ranges | 0-0.05 to 100 ppm |
Zero Noise | 1.0 ppb Manual H2S or CS 3.0 ppb Auto (10 second averaging time) 0.5 ppb 1.5 ppb (60 second averaging time) 0.25 ppb 0.75 ppb (300 second av |
Lower Detectable Limit | 2.0 ppb Manual H2S or CS 6.0 ppb Auto (10 second averaging time) 1.0 ppb 3.0 ppb (60 second averaging time) 0.5 ppb 1.5 ppb (300 second aver |
Zero Drift | Less than 1 ppb |
Span Drift | #ERROR! |
Response Time | 80 seconds (10 second average time) 110 seconds (60 second average time) 320 seconds (300 second average time) |
Precision | 1% of reading or 1 ppb (whichever is greater) |
Linearity | #ERROR! |
Sample Flow Rate | 1.0 liter/min |
Converter Efficiency | > 80% H2S to SO2. Note: Various other Sulfur compounds can be converted at varying % |
Operating Temperature | 20°C-30°C |
Power Requirements | 100 vac 115 vac 220-240 vac +/- 10% @ 300W |
Outputs | Selectable Voltage RS232/RS485 TCP/IP 10 Status Relays and Power Fail Indication (standard). 0-20 or 4-20 mA Isolated Current Outout (op |
Inputs | 16 Digital Inputs (standard) 8 0-10vdc Analog Inputs (optional) |
Dimensions | US: 16.75 x 8.62 x 23 in. Metric: 42.5 x 21.8 x 58.4 cm |