The AreaRAE Gamma Steel is a combination Multi Gas and radiation
detector equipped with a wireless, RF (radio-frequency)modem that allows
the unit to communicate and transmit sensor and other information on a
real-time basis with a remotely located base controller.
In the stand alone operation, the AreaRAE Gamma Steel is a rugged,
weather-resistant, one-to-five sensor portable monitor that can run up
to 24 hours on either rechargeable Lithium-ion or optional alkaline
batteries. It is also the first “lunchbox”- type multi-sensor instrument
able to include a gamma sensor for measurement of gamma radiation, a
photoionization detector (PID) for parts-per-million measurement of
volatile organic compounds (VOCs), as well as an LEL combustible gas
sensor, oxygen sensor, and a selectable electrochemical toxic sensor.
The RF modem allows real-time data transmissions with a base
controller located up to two miles (3.2 km) away from the AreaRAE Gamma
Steel detector. A personal computer can be used as the base station. The
standard ProRAE Remote software used to control AreaRAE Gamma Steel
systems is capable of monitoring the input of up to 32 remotely located
monitors.
Key Features
Up to four gas sensors (PID, LEL, O2 and selectable toxic gas)
One radiation sensor (Gamma)
Loud buzzer and large, extra-bright warning light
Large LCD display and keypad
Real-time wireless data transmission with built-in RF modem
View real-time sensor data and alarm status at headquarters or command center
License free, ISM band RF transmission with communication range up to 2 miles
Fully hardware and software compatible with standard AreaRAE 5-gas monitoring system
Standard AreaRAE is factory upgradeable to AreaRAE Gamma Steel
Rugged, weather-proof housing (IP55)
Built-in sampling pump
Interchangeable Li-ion or alkaline battery pack
Continuous operation via AC source
Sensor Specifications
Radiation
DER Range
Energy Range
Sensitivity
Gamma
1 to 4000 μR/h (0.01 to 40 μSv/h)
0 060 to 3.0 MeV
>100 cps /μSv/hr
Gas Monitor
Range
Resolution
Oxygen
0 to 30.0%
0.1%
Combustible
1 to 100% LEL
1% LEL
VOCs
0 to 199 ppm 200 to 2,000 ppm
0.1 ppm 1 ppm
Carbon Monoxide
0 to 500 ppm
1 ppm
Carbon Monoxide
10 to 2000 ppm
10ppm
Hydrogen Sulfide
0 to 100 ppm
1 ppm
Sulfur Dioxide
0 to 20.0 ppm
0.1 ppm
Nitric Oxide
0 to 250 ppm
1 ppm
Nitrogen Dioxide
0 to 20.0 ppm
0.1 ppm
Chlorine
0 to 10.0 ppm
0.1 ppm
Hydrogen Cyanide
0 to 100 ppm
1 ppm
Ammonia
0 to 50 ppm
1 ppm
Phosphine
0 to 5.0 ppm
0.1 ppm
Hydrogen Chloride
2 to 15 ppm
1 ppm
Hydrogen Fluoride
2 to 10 ppm
1 ppm
Detector Specifications
Size
9.25" L x 5.0" W x 9.25" D (235mm L x 127mm W x 235mm D) without handle
Weight
8.5 lbs. (3.9 kg) with battery pack
Sensors
Up to five sensors (PID, LEL, Gamma, and two selectable toxics; or PID, LEL, Gamma, O2, and one selectable toxic)
Battery
Rechargeable, 7.4V/4.5Ah, Lithium-ion battery pack with built in
charger (less than 10 hours charge time) or a 6 C-size alkaline battery
pack
Operating Hours
Up to 18 hours continuous operation
Display
2-line, 16-digit LCD with manually activated LED back light
Keypads
3 operation and 4 programming keys
Direct Readout
Instantaneous values, sensor name, high and low values for all
detectors, TWA and STEL values for toxic gases and VOCs, battery voltage
and elapsed time
Alarm
Flashing red LED cluster to indicate exceeded preset limits, low battery or sensor failure
Alarm Setting
Separate alarm limit settings for TWA, STEL, Low and High alarm
Audible Alarm
110dB buzzer at 10cm (typical)
Visual Alarm
Flashing red LED cluster
Alarm Mode
Latching/automatic reset
Datalogging
4,000 points for each sensor with time stamp, serial number, user ID, site ID
Data Storage
20,000 readings (64 hours, 5 channels at 1-minute intervals) in non-volatile memory
Datalog Interval
Programmable 1 to 3600 sec
Communication
Upload data to PC and Download monitor setup from PC through RS-232 link to serial port on PC
EM Immunity
No effect when exposed to 0.43 mW/cm2 RF interference (5-watt transmitter at 12 inches)
Safety Certification
CSA Classified for use in Class I, Division 2, Groups A,B, C, and D (w/ 900 MHz modem)
Frequency
902 to 928 MHz (License-free)
RF Range
Up to 2 miles (900 MHz) - extendable with RAELink Repeaters
Callibration
Two-point field calibration for fresh air and standard reference gas
Sampling Pump
Internal integrated diaphragm pump with programmable High (400cc/min) and Low (300cc/min) flow rate settings