24/7 Technical Support

Teledyne API

Teledyne Advanced Pollution Instrumentation is dedicated to being the market leader in air quality monitoring instrumentation and offers gas analyzers, monitors, and process control instruments which comply with the US Environmental Protection Administration (US EPA), European Union (EN), and other requirements for the measurement of ambient air quality. Utilizing proven measurement principles, TAPI offers instruments that Pine carries for continuous emissions monitoring (CEMs), and ambient air quality monitoring applications.
Teledyne API

 

Teledyne API Products

Teledyne T803 CO2/O2 Analyzer
Teledyne T803 CO2/O2 Analyzer
 

The Model T803 CO2/O2 analyzer combines the non-dispersive infrared measurement principle within the model T801 and the proven paramagnetic measurement principle within the T802 in to a single analyzer.  Both technologies give accurate and reliable results combined with product longevity, providing the best price performance value on the market.

The CO2/O2 analyzer is based on widely accepted sensor techniques producing an excellent, rugged product designed for extractive CEM or RATA applications.

All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the included APIcom™ software.


Teledyne Model T200 Chemiluminescence NO/NO2/NOx Analyzer
Teledyne Model T200 Chemiluminescence NO/NO2/NOx Analyzer
 

The Model T200 NO/NO2/NOx analyzer uses the proven chemiluminescence detection principle, coupled with state-of-the-art electronics to allow accurate and dependable low level measurements for use as an ambient analyzer or dilution CEMS monitor.  A unique AutoZero feature provides superb stability by continuously correcting for zero drift, while advanced Adaptive Filtering allows the analyzer to optimize performance under changing conditions. The Model T200 includes a permeation inlet dryer for ozone generation to provide excellent reliability with no periodic replacement required. A catalytic exhaust ozone scrubber is standard for maximum safety and pump life.  All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/0, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the Ranges: 0-50 ppb to 0-20 ppm,
user selectableincluded APIcom™ software.


Teledyne Model 701 Zero Air System
Teledyne Model 701 Zero Air System
 

The Model 701 is an excellent source of clean, dry air for dilution calibrators. It also may be used as a source of purge air for permeation tube ovens or burner air for FID analyzers.  The regenerative, heatless dryer removes water and produces gas with a dewpoint of less than -20°C (up to 15 SLPM flow rate) independent of the inlet dewpoint and assists in the removal of other gases, greatly increasing the life of the chemical scrubbers.  The basic Model 701 includes an oil and diaphram free pump plus scrubbers to remove SO2, NO, NO2, O3, NH3, and H2S. Optional high performance scrubbers are available to remove CO and Hydrocarbons.  Inlet air is pulled into the pump and routed through a pre-cooler and water trap to remove moisture. The air then passes through the regenerative scrubber for final drying and then to the storage tank.  Tank pressure is monitored and maintained at a preset level by cycling the pump automatically as needed, thereby extending both the pump and scrubber life.  Outlet air then passes through a filter to assure a clean,
dry, analytical zero air supply.  A microcontroller cycles the regenerative dryer and water trap valves preventing the pump from starting against full head pressure. The Model 701 is an ideal accessory to the Model T700 Series Dilution Calibrators or as a zero air source for analyzers.

 


Teledyne Model T100
Teledyne Model T100
 

The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level SO2.  Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon ‘kicker’ and advanced optical design combine to prevent inaccuracies due to interferents.  All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/0, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the
included APIcom™ software.