24/7 Technical Support
Teledyne Model T100 Teledyne API Get Quote
 
Question?

 

 

The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level SO2.  Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon ‘kicker’ and advanced optical design combine to prevent inaccuracies due to interferents.  All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/0, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection using the
included APIcom™ software.

Key Features

  • Ability to log virtually any operating parameter
  • Comprehensive internal data logging with programmable averaging periods
  • Internal zero & span check (optional)
  • Temperature & pressure compensation
  • Adaptive signal filtering optimizes response time
  • 8 analog inputs (optional)
  • Front panel USB connections for peripheral devices and firmware upgrades
  • Ethernet, RS-232, and (optional) USB com ports
  • Large, vivid, and durable color graphics display with touch screen interface
  • Dual ranges and auto ranging
  • Tow-year warranty
  • Ranges: 0-50 ppb to 0-20 ppm, user selectable

Technical Specifications

Ranges: Min: 0-50 ppb Full scale\nMax: 0-20,000 ppb Full scale (selectable,\ndual ranges and auto ranging supported)
Measurement Units: ppb, ppm, µg/m3, mg/m3 (selectable)
Zero Noise: < 0.2 ppb (RMS)
Span Noise: < 0.5% of reading (RMS) above 50 ppb
Lower Detectable Limit: 0.4 ppb
Zero Drift: < 0.5 ppb/24 hours
Span Drift: < 0.5% of full scale/24 hours
Lag Time: 20 seconds
Rise and Fall Time: < 100 seconds to 95%
Linearity: 1% of full scale
Precision: 0.5% of reading above 50 ppb
Sample Flow Rate: 650 cm3/min ±10%
Power Requirements 100V-120V, 220V-240V, 50/60 Hz
Analog Output Ranges 10V, 5V, 1V, 0.1V (selectable)
Recorder Offset: ±10%
Included I/O: 1 x Ethernet: 10/100Base-T\n2 x RS232 (300-115,200 baud)\n2 x USB device ports\n8 x opto-isolated digital outputs\n6 x opto-isolated digital inp
Optional I/O: 1 x USB com port\n1 x RS485\n8 x analog inputs (0-10V, 12-bit)\n4 x digital alarm outputs\nMultidrop RS232\n3 x 4-20mA current outputs
Operating Temperature Range: 5 - 40ºC (with EPA Equivalency)
Dimensions (HxWxD): 7” x 17” x 23.5” (178 x 432 x 597 mm)
Weight: 35.7 lbs (16.2 kg)
US EPA: EQSA-0495-100
MCERTS: Sira MC 050067/04
EN 14212 TÜV Rheinland