24/7 Technical Support
Thermo Scientific ADR1500 Area Dust Monitor Thermo Scientific Get Quote
 
Question?

 

 

The Thermo Scientific Model ADR1500 Dust Monitor utilizes the highly sensitive light-scattering photometer (nephelometer) technology as used in the Thermo Scientific™ pDR series. The intensity of the light scattered by airborne particles passing through the sensing chamber is linearly proportional to their concentration. This optical configuration produces optimal response to particles, providing continuous measurements of the concentrations of airborne particles for total particulate and cut-points ranging from PM10 down to PM1.

The ADR1500 incorporates a temperature and relative humidity (RH) sensor coupled with an internal heater to mitigate the positive bias with elevated ambient RH. Additionally, the flow control is truly volumetric and is maintained through digital feedback of the onboard barometric pressure sensor, temperature sensor and calibrated differential pressure across a precision orifice. The principles of true volumetric flow, as incorporated by the ADR1500, result in an accurate sample volume and precise particle cut-point.

Additional Information:

  • The measured concentration of particulate matter is displayed in real-time on the two-line LCD readout display
  • Additional values can be displayed: run start time and date, time averaged concentrations, elapsed run time and many more
  • Flexible power capabilities allow the ADR1500 to operate on AC (100-240 VAC), external DC (12-24 VDC) or an internal battery
  • Communications options are available for USB, RS-232, analog and wireless capability
  • Compact and durable instrument is ready for rapid deployment and unattended operation
  • A top-mounted handle allows for easy transport and installation with mounting options available for wall, post or tripod locations

Key Features

  • Durable, weatherproof IP65 enclosure
  • Multiple power and communications capabilities
  • Modular optics and long-life primary HEPA filter for ease of servicing
  • Volumetric flow control

Applications

  • Multiple power and communications capabilities
  • Modular optics and long-life primary HEPA filter for ease of servicing
  • Volumetric flow control
  • Durable, weatherproof IP65 enclosure

Technical Specifications

2-sigma Values ±0.5% of reading or ±0.0015mg/m3, whichever is larger, for 10-second averaging time
Accuracy ±5% of reading ±precision) traceable to SAE Fine test dust
Aerodynamic Particle Cut-Point Range 1.0 to 10µm, with optional cyclone accessories
Alarm Averaging Time Real-time (1 - 60 seconds) or STEL (15 minutes)
Alarm Output Load impedance >100kw , Alarm ON = short to ground, Alarm OFF = open
Concentration Measurement Range 0.001 to 400mg/m³ (auto-ranging)
Data Logging Averaging Periods 1 second to 1 hour
Description Area Dust Monitor
Flow Rate Range 1.0 to 3.5L/min.
Height (English) 21 in.
Height (Metric) 431mm
Hertz 50/60Hz
Internal Battery Run Time 1.2L/min. (heater and alarm constantly on) >24-hour run time
Depth (English) 17 in.
Depth (Metric) 215mm
Logged Data Averaged concentrations, temperature, RH, barometric pressure, time/date, and data point number
Optional Cyclones GK 2.05 (Red) primarily for PM4 through PM10, SCC 1.062 (blue) primarily for PM1 through PM4
Particle Size Range 0.1 to 10µm
Precision ±2%, for 1-second averaging time
Real-time Analog Signal 0 to 2V and 4 to 20mA, with selectable full scale ranges between 0.1 and 400mg/m3; 0-0.1, 0-0.4, 0-1.0, 0-4.0, 0-10, 0-40, 0-100 and 0-400,
Real-time Digital Signal Concentration, flow, temperature, relative humidity, barometric pressure, time, date
Repeatability ±0.005mg/m3, for 1-second averaging time
Resolution 0.1µg/m?
RH correction ±0.2% or reading or ±0.0005mg/m3, whichever is larger, for 60-second averaging time
Run Summary Site number, average and max. concentrations, time/date of maximum, number of logged points, start time/date, elapsed time (run duration), a
Scattering Coefficient Range 1.1 x 10-6 to 0.6m-1 (approximately) @ l = 880nm
Serial Interface High speed, USB/RS-232 (reserved for wireless applications), 19,200 baud
Temperature (English) Operating 14° to 122°F
Temperature (Metric) Operating 10° to 50°C
Voltage 100-240VAC, 12/24VDC for solar or auxiliary battery options
Weight (English) 28.5 lb.
Weight (Metric) 12.9kg
Width (English) 17 in.
Width (Metric) 431mm
Item Description Thermo Scientific ADR1500