Ready to Support Professionals Responding to Hurricane Irma & Harvey

We at Pine would like to express our thoughts and concerns to all who have suffered during the recent hurricanes Irma and Harvey. We are here and ready to support our customers with all equipment, supplies and service support needed for crisis response cleanup.

24/7 Technical Support
Detection Instruments OdaLog L2 Hydrogen Sulfide Gas Logger (0 – 1000 PPM) Get Quote
 
Question?

 

 

The OdaLog L2 was designed specifically for the wastewater industry, based on valuable input and feedback from plants, equipment and chemical suppliers and industry consultants Typical applications include locating and monitoring the source of Hydrogen Sulfide gas emissions at pump and lift stations, collection systems, and receiving manholes. Once the source of the odor is determined, the OdaLog L2 can be used to prove the effectiveness of hydrogen sulfide reduction strategies that have been implemented. OdaLog customers cost-justify instruments through chemical savings realized by determining the specific times that the H2S emissions occur.

The OdaLog L2 is small, robust, and capable of extensive data logging. Double O-rings minimize moisture ingress and water damage to the instrument’s electronics. Magnetic switches for zeroing and calibrating and an infrared communications link eliminate outside pin connections and associated corrosion problems. The OdaStat-G Software is used for programming the L2 OdaLog, as well as for downloading the data after completing a logging session. The L2 uses a single lithium battery that lasts up to 12 months, has increased memory capacity, uses a single screw design for simple and effective assembly/disassembly and uses IrDA communication protocol for faster downloading. (

Key Features

  • Certified intrinsically safe
  • Faster downloading
  • Easy to read display
  • Simplifies record management
  • Longer battery life
  • Purpose designed for harsh wastewater environments

Applications

  • Certified intrinsically safe
  • Faster downloading
  • Easy to read display
  • Longer battery life
  • Purpose designed for harsh wastewater environments
  • Simplifies record management

Technical Specifications

Gas H2S
Range 0-1000 ppm
Resolution 1 ppm
Accuracy (Full Scale) 1% Full Scale
Accuracy (@ 20ppm gas, STP) ± 2ppm
Instrument Temp Range -20o C (-4o F) to 50o C (122o F)
Sensor Temp Range -10oC to +40o C 14o F to 104o F)
Instrument Relative Humidity Range 15-90% non-condensing