24/7 Technical Support
TSS Portable Hand-held Turbidity, Suspended Solids, and Sludge Level System Hach Ultra Analytics Get Quote
 
Question?

 

 

Complete TSS Portable Hand-held Turbidity, Suspended Solids, and Sludge Level System; includes meter, probe, rechargeable batteries, charger for rechargeable batteries with four plug adapters, manual, quick start guide and carrying case.

Three Parameters in One Instrument
The Hach TSS Portable Hand-held Turbidity, Suspended Solids, and Sludge Blanket Level Instrument's unique multi-beam alternating light method with infrared diode system gives it a broad measuring range for both turbidity and suspended solids in one portable handheld instrument.

Multiple Calibration Curves for Convenience
It stores up to four different calibration curves for suspended solids and one for turbidity. There's no need for constant re-calibration for different locations or types of sludge.

Easy Sludge Blanket Levels
The sludge blanket level can be measured by setting the units to mg/L, g/L or percent. Calibrate the instrument and then slowly lower the sensor into the clarifier. The suspended solids concentration will significantly increase as it reaches the sludge blanket level. Once the blanket level is reached, examine the sensor cable which is marked every meter to determine the sludge blanket level depth from the water surface.

Air Bubble Compensation for Accuracy
The instrument software automatically compensates for air bubbles to prevent its influence on the measurement. Turbidity is pre-calibrated with a calibration curve stored in the instrument. For suspended solids, each of the calibration curves can be closely adjusted to the laboratory results because each calibration curve can use up to three points per curve plus a zero value.

Durable Materials for Long Life
The probe is made of polished stainless steel with a scratch-resistant sapphire window to withstand harsh environments. Polished stainless steel helps keep particles from sticking to the surface of the probe. The internal memory stores up to 290 measuring values, including time, date, measurement, location, and homogeneity. Three operating modes are available: single, interval, or continuous.

Technical Specifications

Cable Length: 10 m cable with marks for distance
Display: Alphanumerical display, 4 rows of 16 characters
Measurement Modes: Continuous measurement, integration time settings 0 - 1000 seconds
Measuring Principle: Combined multiple beam alternating light method with infrared diode system and beam focusing.;\nTurbidity: 2-channel 90° scattered light mea
Measuring Range TSS-Content: 0.001 to 400 g/L upper range depending on sample characteristics
Measuring Range Turbidity: 0.001 to 9999 FNU
Memory: Up to 290 measuring points
Operating Pressure: 0 to 10 bar (0 to 145 psi)
Operating Temperature Range: 0 to 60 °C
Power: Automatic shut down after 4 minutes (if no button has been pressed and no permanent measurement is activated)
Precision Suspended Solids: less than 4 % or ± 0.001 g/L, whichever is greater
Precision Turbidity: less than 3 % or ± 0.02 NTU whichever is greater
Pressure Range: Max. 10 bar
Protection Class: Probe IP68; Control unit IP 55
Relative Humidity: 0 to 95 %
Resolution: Suspended Solids: 0.01 at 1 to 9.999 g/L
Wavelength: 860 nm