Greyline Instruments PDFM 4.0  Portable Doppler Flow Meter Get Quote
 
Question?

 

 

It's ideal for flow troubleshooting, balancing and checking performance of permanent flow meters. The new PDFM 4.0 is fast and easy to operate – you can mount the sensor on the outside a pipe in less than a minute. Use the built-in keypad and calibration menu to set up the flowmeter for your application. The PDFM 4.0 works on any liquid containing bubbles or solids and is recommended for "difficult liquids" like wastewater, slurries, sludge, chemicals, viscous liquids and abrasives. Measures flow through most metal and plastic pipes including PVC, ductile iron, carbon steel and stainless steel.

The Greyline PDFM 4.0 is AC/DC powered with a built-in battery and charger. With its 4-20mA output you can even use the PDFM 4.0 as a spare transmitter in critical applications. For flow studies and troubleshooting use the built-in 50,000 point Data Logger. Retrieve data logs with 'Greyline Logger' software – included free with each PDFM 4.0. Connect the RS232 output directly to the serial port on your PC or Laptop, or by dial-up connection through modems and phone lines.

Key Features

  • No Calculations - No Programming Codes
  • New Signal Processing for reliable Accuracy
  • Includes 4-20mA Output
  • FREE 'Greyline Logger' software for Windows
  • Built-in 50,000 point Data Logger
  • Simple start-up and Calibration
  • Power for the Whole Day
  • Quick, Easy Flow Measurements from Outside a Pipe

Applications

  • No Calculations - No Programming Codes
  • New Signal Processing for reliable Accuracy
  • Includes 4-20mA Output
  • FREE 'Greyline Logger' software for Windows
  • Built-in 50,000 point Data Logger
  • Power for the Whole Day
  • Quick, Easy Flow Measurements from Outside a Pipe
  • Simple start-up and Calibration

Technical Specifications

Flow Rate Range: 0.25 to 40 ft/sec (0.08 to 12.2 m/sec)
Pipe Size: Ultrasonic Sensor mounts on any pipe from ½\" to 180\" ID (12.5 mm to 4.5 m)
Displays: Numeric Values: large (3/4\" / 19 mm high) 4 digit LCD\nTotalizer/Menu/Status: 16 digit LCD alphanumeric
Power Inputs: Built-in battery (3 amp hour 12VDC) with internal charger\nSwitch selectable 100-160VAC 50/60Hz or 200-260VAC 50/60Hz, 12VDC from external ba
Outputs: 4-20mA (500 ohm) with programmable offsets\nRS232 for Data Log transfer by direct PC connection or dial-up through phone lines and modems. Se
Sensor - Standard Model PSE5: Strap-on, single-head ultrasonic for pipes from ½\" to 180\" ID (12.5 mm to 4.5 m) with\n12 ft (3.4 m) shielded dual-coaxial cable
Sensor Mounting Kit: Stainless steel pipe clamp and 5.3 oz. (150 g) silicone coupling compound
Operating Temperature: -40° to 200°F (-40° to 93°C)