The Fluke 1625 is the advanced earth ground tester that performs all four types of earth ground tests and includes features that give quicker and more accurate readings.

 

Testing Methods

  • 3- and 4-Pole Fall of Potential – standard earth ground testing using two ground stakes
  • Selective testing – without disconnecting ground rods, a technician can measure ground resistance using a combination of stakes and a clamp.
  • Stakeless testing – innovative solution using only clamps, instead of ground stakes, to measure earth ground loop resistance

The Fluke 1625 offers these advanced features

  • Automatic Frequency Control (AFC) – identifies existing interference and chooses a measurement frequency to minimize its effect, providing a more accurate earth ground value.
  • R* measurement – calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to-earth ground would see.
  • Adjustable limits – for quick test result verification.

Key Features

  • Programmable limits, settings
  • Measuring voltage switchable 20/48V
  • Automatic frequency control (AFC) (94, 105, 111, 128 Hz)
  • Earth impedance measurement at 55 Hz
  • Stakeless testing, quick ground loop testing (2 clamps)
  • Selective testing, no disconnection of ground conductor (1 clamp)
  • 2- and 4-pole resistance measurement DC
  • 2-pole resistance measurement AC
  • 4-Pole soil resistivity testing
  • Continuity with buzzer
  • 3- and 4-pole earth ground measurement

Technical Specifications

Measuring voltage 250 mA AC
Measure frequency 94, 105, 111, 128Hz
Resolution 0.001 O to 100 O
Measuring range 0.001 O to 299.9 kO
Intrinsic error ± (2 % of reading + 2 d)
Operating error ± (5 % of reading + 5 d)
Measuring voltage Vm = 20/48 V AC
Short circuit current 250 mA AC
Measure frequency 94, 105, 111, 128Hz
Resolution 0.001 O to 100 O
Measuring range 0.001 O to 299.9 kO
Intrinsic error ± (2 % of reading + 2 d)
Operating error ± (5 % of reading + 5 d)
Measuring voltage Vm = 20/48 V AC
Short circuit current 250 mA AC
Measure frequency 94, 105, 111, 128Hz
Resolution 0.001 O to 10 O
Measuring range 0.001 O to 29.99 kO
Intrinsic error ± (7 % of reading + 2 d)
Measuring voltage Vm = 20/48 V AC
Short circuit current 250 mA AC
Measure frequency 94, 105, 111, 128Hz
Resolution 0.001 O to 10 O
Measuring range 0.001 O to 29.99 kO
Intrinsic error ± (7 % of reading + 2 d)
Operating error ± (10 % of reading + 5 d)
Measuring voltage Vm = 20/48 V AC
Measure frequency 94, 105, 111, 128Hz
Noise current (Iext) Max. Iext = 3 A
Resolution 0.001 O to 10 O
Measuring range 0.001 O to 29.99 kO
Intrinsic error ± (7 % of reading + 2 d)
Operating error ± (10 % of reading + 5 d)
Working temperature -10 °C to +50 °C
Operating temperature 0 °C to +35 °C
Nominal temperature +18 °C to +28 °C
Storage temperature -30 °C to +60 °C
Climatic class C1 (IEC 654-1), -5 °C to + 45 °C, 5 % to 95 % RH
Protection type IP56 for case, IP40 for battery door according to EN 60529
Safety rating CAT II, 300 V