This thermal Imager is the perfect tool to add to your problem solving arsenal. Built for tough work environments, this high-performance, fully radiometric infrared camera is ideal for troubleshooting electrical installations, electro-mechanical equipment, process equipment, HVAC/R equipment and others.
IR-Fusion® Technology
See things both ways—infrared and visual (visible light) images combined together communicating critical information faster and easier—traditional infrared images are no longer enough. IR-Fusion, a patent-pending technology that simultaneously captures a digital photo in addition to the infrared image and combines it together, taking the mystery out of IR image analysis. IR-Fusion is standard on Fluke Ti25.
Temperature measurement range (not calibrated below -10 °C) | -20 °C to +350 °C (-4 °F to + 662 °F) (two ranges) |
Temperature measurement accuracy | ± 2 °C or 2 % (whichever is greater) |
On-screen emissivity correction | Yes |
Field of view | 23° x 17° |
Spatial resolution (IFOV) | 2.5 mRad |
Minimum focus distance | Thermal lens: 15 cm (6 in)\nVisible (visual) light lens: 46 cm (18 in) |
Focus | Manual |
Image frequency | 9 Hz refresh rate |
Detector type | 160 X 120 focal plane array, uncooled microbolometer |
Infrared lens type | 20 mm F = 0.8 lens |
Thermal sensitivity (NETD) | = 0.09 °C at 30 °C target temp. (90 mK) |
Infrared spectral band | 7.5 µm to 14 µm |
Visual camera | 640 x 480 resolution |
Voice annotation | 60 seconds maximum recording time per image; reviewable playback on imager |
Storage medium | SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice an |
File formats | Non-radiometric (.bmp) or fully-radiometric (.is2) No analysis software required for non-radiometric (.bmp) files |
Export file formats w/SmartView® software | JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, and EMF |
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) without batteries |
Relative humidity | 10 % to 90 % non-condensing |
Display | 9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD with backlight (selectable bright or auto) |
Controls and adjustments | User selectable temperature scale (°C/°F)\nLanguage selection\nTime/Date set |