24/7 Technical Support
Global WS750 Wastewater/Stormwater Sampler Get Quote
 
Question?

 

 

The new WS750 two-bottle wastewater/stormwater samplers combine all the features you need to meet a wide variety of sampling requirements, including those for stormwater, industrial discharge, water and wastewater treatment, waste collection systems, and rivers and streams.

The WS750 wastewater/stormwater sampler's state of the art controller gives you complete control over your wastewater/stormwater sampling process.  With the wastewater/stormwater sampler's sample size control, you can take individual time-weighted composite samples or full-bottle discrete grab samples.  The wastewater/stormwater sampler's sample interval control allows you set the time between individual composite samples or enable the external trigger mode.  A start delay timer allows you to start multiple wastewater/stormwater samplers in the field at the same time, or to delay drawing a wastewater/stormwater sample after a triggering event so that your sample better represents the water source.  An automatic15 second backflush cycle clears any debris from the wastewater/stormwater sampler's strainer and empties the water from the hose so the next sample is not contaminated.

A unique feature of the WS750 stormwater/wastewater samplers is the ability to set the sampling mode for each pump and bottle individually.  This allows you to take two individual time-weighted or flow proportional composite samples, or you can set the stormwater/wastewater samplers to take full-bottle discrete (grab) samples, or you can set the stormwater/wastewater samplers to take a full-bottle discrete (grab) sample in one bottle and a time-weighted or flow proportional composite sample in the other.  In the case of two composite samples you can have different size settings for each pump.

The WS750 stormwater/wastewater samplers are easy to set up in the field.  The stormwater/wastewater samplers rugged rainproof enclosure can be padlocked and/or chained to prevent tampering.  The stormwater/wastewater samplers are enclosed in a relatively small case that can be easily hidden or camouflaged to prevent vandalism.  The stormwater/wastewater sampler's is lightweight enough that even with a full sample bottle it can be suspended in a manhole for stormdrain or sewer sampling.

The WS750 wastewater/stormwater samplers come with two 1-gallon polyethylene sample bottles for collecting composite samples, two peristaltic sampling pump, a circuit board controller, and a rechargeable gel cell battery.  Also provided are two sample pickup hoses and a battery charger.  Everything you need is provided for a successful wastewater management or environmental monitoring program.

- CE Certified
- Does composite, discrete or both types of sampling
- Simple to operate - no programming required
- Output provided for use with optional datalogger
- Lightweight and easy to carry
- Rugged construction for harsh environments
- Meets federal, state and local wastewater regulations
- Timed and external flow proportional sampling
- Adjustable and repeatable sample volume
- Peristaltic pump prevents sample contamination
- Automatic backflush clears pickup strainer and hose
- Rechargeable battery or AC powered
- The easiest and most reliable method for collecting water quality samples

 

 

Key Features

  • Remote Water Sampling Notification - Attach the AD200 Autodialer or CVD-2000P Cellular Autodialer to your wastewater/stormwater sampler to add remote sample notification. This accessory will save you travel time by ensuring that you always know when your wastewater/stormwater water samplers have taken a sample at your monitoring sites.
  • Flow Proportional Sampling - An external pulse-type flow meter can control the water sample interval for true flow proportional sampling.
  • Sample Size - The user can adjust the wastewater/stormwater sampler's peristaltic pumps individually to one of 15 composite sample sizes from 50ml to 2 liters plus a full bottle discrete setting. The wastewater/stormwater sampler's peristaltic pumps can be set to a single sample time interval from 5 minutes to 12 hours plus an external trigger mode setting for flow proportional sampling.
  • Overflow Protection - The wastewater/stormwater sampler's sample bottles are each equipped with a float switch that automatically turns off the peristaltic sampling pump if the water bottle becomes full.
  • Lower Power - The composite/discrete water sampler's 5 AH rechargeable battery will power the sampler for several months or a half hour of continous sampling with both pumps.

Applications

  • Flow Proportional Sampling - An external pulse-type flow meter can control the water sample interval for true flow proportional sampling.
  • Sample Size - The user can adjust the wastewater/stormwater sampler's peristaltic pumps individually to one of 15 composite sample sizes from 50ml to 2 liters plus a full bottle discrete setting. The wastewater/stormwater sampler's peristaltic pumps can be set to a single sample time interval from 5 minutes to 12 hours plus an external trigger mode setting for flow proportional sampling.
  • Overflow Protection - The wastewater/stormwater sampler's sample bottles are each equipped with a float switch that automatically turns off the peristaltic sampling pump if the water bottle becomes full.
  • Lower Power - The composite/discrete water sampler's 5 AH rechargeable battery will power the sampler for several months or a half hour of continous sampling with both pumps.
  • Remote Water Sampling Notification - Attach the AD200 Autodialer or CVD-2000P Cellular Autodialer to your wastewater/stormwater sampler to add remote sample notification. This accessory will save you travel time by ensuring that you always know when your wastewater/stormwater water samplers have taken a sample at your monitoring sites.

Technical Specifications

Operating Temperature: 32° to +158°F (0° to +70°C)
Materials: Enclosure: Expanded UV protected PVC\nBottles: Two 1-gallon Polyethylene\nPickup Hose: 15 ft reinforced PVC 1/4\" ID polyethylene flexible t
Sample Pump: Flow Rate: 1000 ml per minute at a 4 foot head\nType: Peristaltic\nMaxiumum Lift: ~20 feet
Battery: Rechargeable 5AH Gel Cell
Battery Life: One Pump running: ~1 hour Two Pumps running: ~ ½ hour\nStandby: 3 months while retaining enough power to run the pump to capacity\n
Start Delay: 16 time settings from 0-12 hrs
Composite Interval: 15 time settings from 5 min. to 12 hours plus an External Trigger mode setting
Sample Size: 15 composite sample sizes from 50ml to 2 liters plus a Full Bottle discrete setting (Approximate sizes at 4 foot head)
External Trigger Input: 250mS minimum pulse width\nSwitch closure or 4-30VDC
Pulse Output: 5VDC one-second pulse\n1000 ohm output impedance
Bottle Switch Input: Switch closure Input\nFloating read switch in bottle
Rain and Water Sensors: Optional moisture sensors or switch closure inputs
Internal Fuse: 10A Slow-Blow
Size of Unit: 22 x 17 x 9 inch (56 x 43 x 23 cm) (H x W x D)
Weight 22 lbs. (Shipping Weight: 24 lbs)