AreaRAE Steel is a multi-gas, wireless monitor. Housed in a stainless-steel enclosure, it is rugged, portable and weather resistant, ensuring that it can withstand harsh environments. The AreaRAE Steel can monitor up to five threats, including VOCs, LEL, Oxygen, and two user-selectable toxic sensors. Strategically placed AreaRAE Steel monitors can be used to quickly establish a perimeter, allowing individuals to back off to a safe position and receive readings from up to 2 miles (3 km) away.

Key Features

  • Up to five sensors (PID, LEL, O2 and two toxic)
  • Wireless data transmission up to 2 miles (3km)
  • Built-in sampling pump
  • Optional GPS
  • Loud buzzer and large, extra-bright warning light
  • Large LCD display and keypad
  • Interchangeable Lithium-ion or alkaline battery pack
  • Rugged, stainless-steel housing
  • Weather-resistant
  • Continuous operation via AC source

Applications

  • HazMat and Emergency Response
  • Refineries and Petrochemical Plants
  • Power Plants

Technical Specifications

Size 9.25'' L x 5.0'' W x 9.25'' D (235mm L x 127mm W x 235mm D) without handle
Weight 13.85 lbs (6.3 kg) with battery
Sensors Up to five sensors (O2, combustible, two toxic and VOC), electrochemical sensors for toxic gases and oxygen, photoionization detector for VOC, catalytic combustion sensor for combustible gases
Battery Rechargeable, 7.4V/4.5Ah,Lithium-ion battery pack with built-in charger (lessthan 10 hourscharge time) or a 6 C-size alkaline battery pack
Operating Hours Up to 18 hours continuous operation
Display 2-line, 16-digit LCD with manually activated LED back light
Keypads 3 operation and 4 programming keys
Direct Readout Instantaneous values, sensor name, high and low values for all detectors, TWA and STEL values for toxic gases and VOCs, battery voltage and
Alarm Flashing red LED cluster to indicate exceeded preset limits, low battery or sensor failure
Alarm Setting Separate alarm limit settings for TWA, STEL, Low and High alarm
Audible Alarm 110dB buzzer at 10cm (typical)
Visual Alarm Flashing red LED cluster
Alarm Mode Latching/automatic reset
Datalogging 4,000 points for each sensor with time stamp, serial number, user ID, site ID
Data Storage 20,000 readings (64 hours, 5 channels at 1-minute intervals) in non-volatile memory
Datalog Interval Programmable 1 to 3600 sec
Communication Upload data to PC and Download monitor setup from PC through RS-232 link to serial port on PC
EM Immunity No effect when exposed to 0.43 mW/cm2 RF interference (5-watt transmitter at 12 inches)
Safety Certification CSA Classified for use in Class I, Division 2, Groups A,B, C, and D (w/ 900 MHz modem)
Wireless Frequency 902 to 928 MHz (License-free)
RF Range Up to 2 miles (900 MHz) - extendable with RAELink Repeaters
Callibration Two-point field calibration for fresh air and standard reference gas
Sampling Pump Internal integrated diaphragm pump with programmable High (400cc/min) and Low (300cc/min) flow rate settings
Low Flow Alarm Auto shut off pump at low flow condition
Temperature -4° to 113°F (-20° to 45°C)
Humidity 0% to 95% relative humidity (non-condensing)
Optional Integrated GPS receiver

Dimensions

  US Metric
Dimensions 9.25"Lx 5.0" W x 9.25" D without handle 235mm Lx 127mm W x 235mm D without handle

Weight

  US Metric
Weight 13.85 lbs (with battery) 6.3 kg (with battery)