This second generation OmniScan MX2 increases testing efficiencies, ensuring superior manual and advanced AUT application performance with faster setups, test cycles, and reporting, in addition to universal compatibility with all phased array and ultrasound modules: past, present and future. Designed for NDT leaders, this high-end, scalable platform delivers true next-generation NDT performance.

The OmniScan MX2 offers a high acquisition rate and new powerful software features for efficient manual and automated inspection performance—all in a portable, modular instrument.

Powerstart your day the right way with the OmniScan MX2. The OmniScan MX2 simplifies and speeds up the setup process with its intuitive Weld Overlay software feature, so you can start testing immediately. Featuring the industry-standard phased array user interface with faster-than-ever performance, a bigger and brighter 10.4 inch screen, new and unique intuitive touch-screen capabilities, and faster data transfer, enabling you to get to your next inspection quicker.

State of the Art PA2 and UT2 Modules - As a world leader in phased array technology, Olympus has just released a new line of modules compatible with MX2 instrument.

PA2 - The new phased array offer—led by the new innovative PA2 modules, features multiple improvements, such as:

Best Phased Array and TOFD Signal Quality Ever
• Better signal-to-noise ratio
• More powerful pulsers
• 64 pure gray tone

More Multi-group CapabilitiesBright, Large Touch Screen
• Ability to use PA and UT channels simultaneously

General Hardware Improvements
• Higher operating temperatures (45 °C)
• New OmniScan probe connector with quick latch system
• Designed for IP66 environmental rating
• Extended autonomy on batteries

UT2 - The new Conventional Ultrasound module features the same technology of UT channels as the PA2 modules, but offers twice as many channels.

Key Features

  • Bright, Large Touch Screen
  • New OmniPC Analysis Software
  • New NDT SetupBuilder Design Software
  • New Phased Array and TOFD Modules

Applications

  • New OmniPC Analysis Software
  • New NDT SetupBuilder Design Software
  • New Phased Array and TOFD Modules
  • Bright, Large Touch Screen

Technical Specifications

Storage devices SDHC card, most standard USB storage devices or fast Ethernet
Data file size 300 MB
USB ports 3
Speaker out Yes
Video output Video out (SVGA)
Ethernet 10/100 Mbps
Encoder 2-axis encoder line (quadrature, up, down, or clock/direction)
Digital input 4 digital TTL inputs, 5 V
Digital output 4 digital TTL outputs, 5 V, 15 mA
Acquisition on/off switch Remote acquisition enabled TTL, 5V
Power output line 5 V, 500 mA power output line (short-circuit protected)
Alarms 3 TTL, 5 V, 15 mA
Analog output 2 analog outputs (12 bits) ±5 V in 10 kO
Pace input 5 V TTL pace input
Display size 26.4 cm (10.4 in.) (diagonal)
Resolution 800 pixels x 600 pixels
Brightness 700 cd/m2
Number of colors 16 million
Type TFT LCD
Battery type Smart Li-ion battery
Number of batteries 1 or 2 (battery chamber accommodates two hotswappable\nbatteries)
Battery life Minimum 7 hours with two batteries
Operating temperature\nrange -10 °C to 45 °C\n(14 ºF to 113 ºF)
Storage temperature range –20 °C to 60 °C (–4 ºF to 140 ºF) with batteries\n–20 °C to 70 °C (–4 ºF to 158 ºF) without batteries
Relative humidity Max. 70% RH at 45°C noncondensing
Ingress Protection Rating IP54
Shockproof rating Drop-tested according to MIL-STD-810G 516.6
Connectors 1 Phased Array connector: Olympus PA connector\n2 UT connectors: LEMO 00
Number of focal laws 256
Probe recognition Automatic probe recognition
Aperture 32 elements
Number of elements 128 elements
PULSER PA CHANNELS
Voltage 40 V, 80 V, and 115 V
Pulse width Adjustable from 30 ns to 500 ns, resolution of 2.5 ns
Pulse shape Negative square wave
Output impedance < 25 O
RECEIVER PA CHANNELS
Gain 0 dB to 80 dB, maximum input signal\n550 mVp-p (full-screen height)
Input impedance 65 O
System bandwidth 0.6 MHz to 18 MHz\n(–3 dB)
Scan type Sectorial and linear
Group quantity Up to 8
Aperture 32
Number of elements 128
Digitizing frequency 400 MHz (12 bits) after interpolation per 4*
Maximum pulsing rate Up to 10 kHz (C-scan)
Number of data points Up to 8,192
Real-time averaging PA: 2, 4, 8, 16\nUT: 2, 4, 8, 16, 32, 64
Rectifier RF, full wave, half wave +, half wave –
Filtering PA Channel: 3 low-pass, 3 band-pass, and 5 high-pass\nfilters.\nUT channel: 3 low-pass, 6 band-pass, and 3 high-pass\nfilters (8 low-pass filte
Video filtering Smoothing (adjusted to probe frequency range)
A-scan refresh rate Real time: 60 Hz
On internal clock 1 Hz to 10 kHz
On encoder On 2 axes: from 1 to 65,536 steps
Number of points 32: One TCG curve per focal law
Number of alarms 3
Conditions Any logical combination of gates
Analog outputs 2

Dimensions

  US Metric
Dimensions 8.9 x 7.2 x 1.6 in 226 x 183 x 40 mm

Weight

  US Metric
Weight 3.5 lb 1.6 kg