Thermo 15I Thermo Scientific Get Quote
 
Question?

 

 

Now available for rent, model 15i HCl analyzer. Using gas filter correlation technology, the Model 15i HCl measures the amount of Hydrogen Chloride in the sample. The Model 15i is based on the principle that Hydrogen Chloride (HCl) absorbs infrared radiation at a wavelength of 3.4 microns. Because infrared absorption is a nonlinear measurement technique, it is necessary for the instrument electronics to transform the basic analyzer signal into a linear output. The Model 15i HCl uses an exact calibration curve to accurately linearize the instrument output over any range up to a concentration of 5,000ppm. This state-of-the-art gas analyzer offers features such as an ethernet port, flash memory for increased data storage as well as being field upgradable. Ethernet connectivity provides efficient remote access, allowing the user to download measurement information directly from the instrument without having to be on-site. Easily programmable shortcut-keys allow you to jump directly to frequently accessed functions, menus or screens The larger interface screen can display measurement information and status while viewing menu and operational screens.

Key Features

  • Flash memory for increased data storage and user downloadable software
  • Ethernet connectivity for efficient remote access
  • Enhanced user interface with one button programming and large display screen
  • Improved layout for easier accessibility to components
  • Enhanced electronics design optimizes product commonality

Technical Specifications

Preset Ranges 0-5, 10, 20, 50, 100, 200, 500, 1000, 2000, and 5000 ppm
Custom Ranges 0-5 to 5000 ppm
Zero Noise 0.1 ppm RMS (5 minute averaging time)
Lower Detectable Limit 0.20 ppm
Zero Drift +/- 0.2 ppm
Span Drift +/-2% full scale
Response Time 120 seconds (30 second average time)
Precision +/- 0.1 ppm
Linearity +/-2% full scale < 1000 ppm, +/- 5% full scale >1000 ppm
Sample Flow Rate 1.0 liters/min. nominal
Operating Temperature 5°C - 45°C
Power Requirements 100 vac, 115 vac, 220-240 vac +/-10% @ 275W
Outputs Selectable Voltage, RS232/RS485, TCP/IP, 10 Status Relays, and Power Fail Indication (standard). 0-20 or 4-20 mA Isolated Current Output (op
Inputs 16 Digital Inputs (standard), 8 0-10vdc Analog Inputs (optional)

Dimensions

  US Metric
Dimensions 16.75(W) x 8.62\"(H) x 23\"(D) 425 mm (W) x 219 mm (H) x 584 mm (D)

Weight

  US Metric
Weight 49 lbs ,22.2 kg\"

Consumables

Calibration Gas
Calibration Gas