24/7 Technical Support
Testo 350 XL Portable Emissions Analyzer Testo Get Quote
 
Question?

 

 

Now available on rental or hire from Pine the Testo 350 XL. With sample conditioning technology and electrochemical sensors, the Testo 350 XL is designed for short-term industrial stack gas monitoring, combustion analysis and Flue Gas Monitoring. The analyzer measures Oxygen (0 to 25%), Carbon Monoxide (0 to 10,000 ppm), Nitric Oxide (0 to 3,000 ppm), Nitrogen Dioxide (0 to 500 ppm), Sulfur Dioxide (0 to 5,000 ppm) and Temperature (-40 to 2,192 F) and calculates Carbon Dioxide (0 to CO2 max. volume %) and Efficiency (0 to 100%). The readings can be printed on board or saved by PC downloading. A complete Peltier gas preparation unit for controlled condensate removal is also standard.

Key Features

  • Optional outdoor case available on request
  • Highly accurate in lower ranges for CO and NO
  • Analysis unit with datalogging function allows measurement without control unit
  • Battery and 240V mains operation
  • Built-in Printer and Internal Datalogger
  • Touchscreen operation for quick operation and input

Applications

  • Optional outdoor case available on request
  • Highly accurate in lower ranges for CO and NO
  • Battery and 240V mains operation
  • Built-in Printer and Internal Datalogger
  • Touchscreen operation for quick operation and input
  • Analysis unit with datalogging function allows measurement without control unit

Technical Specifications

Power Rechargeable NiMH battery, up to 2 hours continuous operation or 115 VAC
Oxygen: Range: 0 to 21% volume Resolution: 0.1% volume Accuracy: 2% of m.v
Carbon Monoxide: Range: 0 to 10,000ppm (H<sub>2</sub>S compensated Resolution: 1ppm Accuracy: 5ppm (0 - 99ppm), 5% m.v (100 - 2,000ppm), 10% m.v (2,001 - 10,
Nitrogen Oxide: Range: 0 to 3,000ppm Resolution: 1ppm Accuracy: 5ppm (0 - 99ppm), 5% m.v (100 - 2,000ppm), 10% m.v (2,001 - 10,000ppm)
Nitorgen Dioxide: Range: 0 to 500ppm Resolution: 0.1ppm Accuracy: 5ppm (0 - 99ppm), 5% m.v (100 - 500ppm)
Sulphur Dioxide: Range: 0 to 500ppm Resolution: 0.1ppm Accuracy: 5ppm (0 - 99ppm), 5% m.v (100 - 500ppm)
Temperature: Range: -40°C to +1,200°C Accuracy: 0.5°C (-40°C to +99°C), 0.5% m.v (+100°C to +1,200°C)
Carbon Dioxide: Range: 0 to CO<sub>2</sub> max volume % Resolution: 0.1% volume Accuracy: Calculated from Oxygen
Efficiency: Range: 0 to 100%
Power: Rechargeable NiMH (2hours operation) or 240V AC mains

Dimensions

  US Metric
Dimensions 16 x 11\" x 4\"\" 406 x 279 x 101 mm

Weight

  US Metric
Weight 9 lbs 4 kg