24/7 Technical Support
Raytek Ranger Raytek Get Quote
 
Question?

 

 

Handheld and portable, the Raytek STProPlus IR (infrared) thermometer measures surface temperatures, helping to quickly locate potential blockages or malfunctioning systems.

Key Features

  • Probe Jack
  • MIN,MAX, AVG, DIF Temp. Display
  • Locking Trigger
  • LCD Backlit
  • Hi/Low Alarm
  • Display Hold (7 seconds)

Applications

  • MIN,MAX, AVG, DIF Temp. Display
  • Locking Trigger
  • LCD Backlit
  • Hi/Low Alarm
  • Display Hold (7 seconds)
  • Probe Jack

Technical Specifications

Temperature Range -32 to 600°C (-25 to 1100°F)
Accuracy (assumes ambient Op Temp of 23°C) ((73°F) -32 to -26°C (-25 to -15°F): ±3°C (±5°F) -26 to -18°C (-15 to 0°F): ±2.5°C (±4°F) -18 to 23°C (0 to 73°F): ±2°C (±3°F)
Repeatability ±0.5% or less or equal to ±1ºC (±2ºF), whichever is greater
Response Time Less or equal to 0.5 second (95% of reading)
Spectral Response 8-14 µm
Emissivity** Digitally Adjustable Emissivity (from 0.1 to 1.0 by 0.01)
Ambient Operating Temp. 0 to 50°C (32 to 120°F)
Relative Humidity 10-90% RH noncondensing, at <30°C (86°F) ambient
Storage Temperature -20 to 60°C (-13 to 158°F) without battery
Power 9V Alkaline or NiCd Battery
Battery Life (Alkaline) 20 hrs w/laser & backlight on 50% 40 hours w/laser & backlight off
Laser Sighting (Class II) Extra Bright Laser Point
Typical Distance to Target 5m (15 ft)
Distance to Spot (D:S) 30:1 at focus point
Data Logging 12 points
Temperature Display °C or °F selectable
Display Resolution 0.1°C (0.1°F)
Temperature Range -32 to 600°C (-25 to 1100°F)
Accuracy (assumes ambient Op Temp of 23°C) ((73°F) -32 to -26°C (-25 to -15°F): ±3°C (±5°F) -26 to -18°C (-15 to 0°F): ±2.5°C (±4°F) -18 to 23°C (0 to 73°F): ±2°C (±3°F)
Repeatability ±0.5% or less or equal to ±1ºC (±2ºF), whichever is greater
Response Time Less or equal to 0.5 second (95% of reading)
Spectral Response 8-14 µm
Emissivity** Digitally Adjustable Emissivity (from 0.1 to 1.0 by 0.01)
Ambient Operating Temp. 0 to 50°C (32 to 120°F)
Relative Humidity 10-90% RH noncondensing, at <30°C (86°F) ambient
Storage Temperature -20 to 60°C (-13 to 158°F) without battery
Power 9V Alkaline or NiCd Battery
Battery Life (Alkaline) 20 hrs w/laser & backlight on 50% 40 hours w/laser & backlight off
Laser Sighting (Class II) Extra Bright Laser Point
Typical Distance to Target 5m (15 ft)
Distance to Spot (D:S) 30:1 at focus point
Data Logging 12 points
Temperature Display °C or °F selectable
Display Resolution 0.1°C (0.1°F)