Pinpoint power quality problems faster, safer and in greater detail with the Fluke 435 power quality analyzer. These three-phase power quality meters help you locate, predict, prevent and troubleshoot problems in power distribution systems. These easy-to-use power quality tools are a “must have” for any person who maintains or troubleshoots three phase power. The new IEC Class A standards for flicker and power quality are built right in to take the guess work out of power monitoring.

Key Features

  • Troubleshoot real-time: Analyze the trends using the cursors and zoom tools even while background recording continues
  • Highest safety rating in the industry: 600 V Cat IV/1000 V CAT III rated for use at the service entrance\r
  • Automatic transient mode: Captures 200 kHz waveform data on all phases simultaneously: Up to 6 kV\r
  • \r

Applications

  • Highest safety rating in the industry: 600 V Cat IV/1000 V CAT III rated for use at the service entrance\r
  • Automatic transient mode: Captures 200 kHz waveform data on all phases simultaneously: Up to 6 kV\r
  • \r
  • Troubleshoot real-time: Analyze the trends using the cursors and zoom tools even while background recording continues

Technical Specifications

Volt/Amps/Hertz Vrms (AC + DC) Measurement range: 1 ... 1000 V Accuracy: 0.1% of Vnom Vpeak Measurement range: 1 ... 1400 V Accuracy: 5% of Vnom Crest factor, voltage Measurement range: 1.0 ... > 2.8 Accuracy: ±5% Arms (AC + DC)
Safety EN61010-1 (2nd edition) pollution degree 2; 1000 V
Autotrend Recording Sampling: 5 readings/sec continuous sampling per channel
Transient Capture Volts Measurement range: ±6000 V
Harmonics Measurement range: DC, 1..50; (Off, 1..49) Vrms Measurement range: 0.0 & 1000 V Accuracy: ±0.05% of nominal voltage Arms Measurement range: 0.0 & 4000 mV x clamp scaling Accuracy: ±5% ± 5 counts Watt Measurement range: Depends on clamp scaling and voltage Accuracy: ±5% ± n x 2% or reading, ± 10 counts DC voltage
Dips and swells Vrms (AC+DC) ² Measurement range: 0.0% & 100% of Vnom Accuracy: ±0.2% of nominal voltage Arms (AC+DC) ²
Inputs Number: 4 voltage and current (3 phases + neutral) Maximum voltage: 1000 Vrms (6 kV peak)
Operating temperature 0 ºC to +50 ºC
Battery Life Rechargeable NiMH pack (installed): >7 hours

Dimensions

  US Metric
Dimensions - 256 x 169 x 64 mm

Weight

  US Metric
Weight - 1.1 kg

Consumables

Personal Protective Equipment (hard hats, glasses, reflective vest, etc)
Personal Protective Equipment (hard hats, glasses, reflective vest, etc)