24/7 Technical Support
ECOM J2KN Portable Emissions Analyzer ECOM Get Quote
 
Question?

 

 

The ECOM J2KN is the “heavy-duty” version of the J2K, with the analyzer and all of it’s outstanding features built into a rugged hard-side, aluminum reinforced case. With wireless remote control, the J2KN’s handheld remote allows complete operation of the analyzer showing all values at a glance, zoom display capability, and plug-in memory up to 256 MB. The tactile keypad guides the operator through the various functions of the analyzer. The remote display feature makes the J2K an ideal emission analyzer where combustion controls are located away from the flue test port on large combustion systems. The J2K can be fitted with up to 5 gas sensors to measure O2, CO, NO, NO2, and Combustibles, along with gas and ambient temperatures, stack draft & pressure, plus calculations of CO2, efficiency, excess air, and oxygen correction to 20%.

Key Features

  • Ambient, Flue Gas, Sensor Temperature Measurement
  • Thermoelectric Gas cooler & Automatic
  • Stack Temperature and Draft Measurement
  • Measures O2, CO, NOx, Low NOx, SO2 and combustibles
  • In-line flowmeter with 3.5+ lpm pump

Applications

  • Thermoelectric Gas cooler & Automatic
  • Stack Temperature and Draft Measurement
  • Measures O2, CO, NOx, Low NOx, SO2 and combustibles
  • In-line flowmeter with 3.5+ lpm pump
  • Ambient, Flue Gas, Sensor Temperature Measurement

Technical Specifications

Measurement - Oxygen (O) Range: 0 - 21% vol.
Carbon Monoxide © Range: 0 - 4,000 ppm
Carbon Monoxide (V) Range: 1 - 40,000 ppm
Nitric Oxide (N) Range: 0 - 4,000 ppm
Nitric Oxide (.N) Range: 0 - 400 ppm
Nitrogen Dioxide (X) Range: 0 - 500 ppm
Nitrogen Dioxide (.X) Range: 0 - 50 ppm
Sulfur Dioxide (S) Range: 0 - 5,000 ppm
Combustibles (H) Range: 0 - 6.00 % vol
Gas Temperature Range: 32 - 1800 F
Ambient Temperature Range: 0 - 250 F
Draft / Pressure Range: ± 40\" H2O
Operating Temperature Core temperature of the instrument is monitored continuously. Internal Temperature Compensation software assures accurate sensor response ov
Display Backlit, adjustable contrast and zoom, displays all parameters simultaneously.
Sample Line 15' high-temp flex hose w/thermocouple wire

Dimensions

  US Metric
Instrument 16\" x 10\" x 12\" -
Probe 13\" Length x 3/8\" OD -

Weight

  US Metric
Instrument 28 lbs -