24/7 Technical Support

Pine has a Tier1 partnership with Airgas in order to provide protocol calibration gases to our CEMS customers. Working closely with Airgas, Pine has taken a “best of breed” approach to building gas handling systems, testing manifolds and regulator clean out stations, all designed by Airgas. Pine is the only Tier 1 partner to take advantage of this high level of QA/QC in order to manage calibration gases and equipment in the US.

The most common Protocols we carry are:

  • Oxygen/Carbon Dioxide (O2/CO2)
  • Carbon Monoxide (CO)
  • Nitrogen Oxides (NOx)
  • Sulphur Dioxide (SO2)
  • Propane and Methane

Pine carries protocol gases to offset the just in-time needs by customers who require the protocol gases to run their processes or shut down. Customers under EPA regulations CFR 40 part 60 and part 75 use our services as well as stack testing professionals performing CFR 40 Part 60 Appendix A analyzer method compliance sampling, namely Methods 3A, 6C, 7E, 10A.

Pine carries most protocols in values of 0-10ppm and up to 1% we also have specialty gases for HCl, NH3, HCHO, and speciated volatiles. Please contact us today and we will find the right fit for your needs.

Pine provides a first-class technical support service as well as advice on which product will be best suited to your needs. Our quality management system insures that all equipment is tested and calibrated to manufacturer’s specifications when you receive it. To find out more, please select from the products listed below.


Carbon Monoxide (CO)
Carbon Monoxide (CO)

Protocol Carbon Monoxide Gases in balance Nitrogen are available in span ranges from 0-10 ppm up to 10% (100,000 ppm). Carbon Monoxide standards are used to calibrate Continuous Emission Monitors designed to measure CO for compliance reporting. Applicable EPA methods: USEPA Method 10 & CFR 40 Part 60 Performance Specification 4.

show more

Hydrogen Chloride
Hydrogen Chloride

Protocol Hydrogen Chloride Gases in balance Nitrogen are available in span ranges from 0-50 ppm up to .5% (5,000 ppm). Hydrogen Chloride standards are used to calibrate instruments designed to measure HCL for compliance reporting. Applicable EPA methods: USEPA Method 321.

show more

Nitrogen Oxides (NOx)
Nitrogen Oxides (NOx)

Protocol Nitric Oxide Gases in balance Nitrogen are available in span ranges from 0-10 ppm up to 1% (10,000 ppm). Nitric Oxide standards are used to calibrate Continuous Emission Monitors designed to measure NOx for compliance reporting. Applicable EPA methods: USEPA Method 7E, CFR 40 Part 60 Performance Specification 2 & CFR 40 Part 75.

show more

Oxygen / Carbon Dioxide (O2/CO2)
Oxygen / Carbon Dioxide (O2/CO2)

Protocol Oxygen/Carbon Dioxide Gases are available in span ranges from 0-25%. Carbon Dioxide standards are used to calibrate Continuous Emission Monitors designed to measure CO2 for compliance reporting. Applicable EPA methods: USEPA Method 3, CFR 40 Part 60 Performance Specification 3 & CFR 40 Part 75.

show more

Propane (C3H8)
Propane (C3H8)

Protocol Propane Gases in balance air are available in span ranges from 0-10 ppm up to 10% (100,000 ppm). Propane standards are used to calibrate FID instruments designed to measure Total Hydrocarbon Emission for compliance reporting. Applicable EPA methods: USEPA Method 25A & CFR 40 Part 60 Performance Specification 8A.

 

show more

Sulfur Dioxide (SO2)
Sulfur Dioxide (SO2)

Protocol Sulfur Dioxide Gases in balance Nitrogen are available in span ranges from 0-50 ppm up to 1% (10,000 ppm). Sulfur Dioxide standards are used to calibrate Continuous Emission Monitors designed to measure SO2 for compliance reporting. Applicable EPA methods: USEPA Method 6C, CFR 40 Part 60 Performance Specification 2 & CFR 40 Part 75.

show more