24/7 Technical Support

Our PIDs, FIDs and VOC monitors are ideal for applications in hazardous material response, confined space entry and personnel or workplace monitoring. With manufactures like RAE Systems, Photovac and Thermo Environmental, you can rest assured you are getting the very best in the industry. We stock multiple models and sizes, and are guaranteed to have the instrument to fit your job’s needs.

To find out more, please click on a product from the list.  At Pine, we specialize in delivering total equipment solutions and providing technical advice on what to rent, and how to use it; the availability of our rental fleet is second to none, and all our equipment is always tested and delivered ready to use.


FOXBORO TVA1000A PID/FID
FOXBORO TVA1000A PID/FID

The TVA-1000 incorporates both a PID and an FID, eliminating the need for two different instruments. It provides fast and accurate readings of organic and inorganic vapors and meets EPA Method 21 specifications for monitoring fugitive emissions. Measurements are indicated on two digital displays: an LCD on the control panel simultaneously indicates readings from both detectors, while the field- sampling display on the probe shows one concentration at a time. Data is collected and stored at user programmable intervals and can be downloaded to a PC using software that comes with the rental unit. The TVA-1000 is housed in a NEMA Type 3 enclosure. UHP hydrogen fuel is available for purchase.

show more

FROG-4000 VOC Analyzer
FROG-4000 VOC Analyzer

Defiant Technologies’ FROG-4000TM is a hand held micro system for detection of benzene, toluene, ethylbenzene, and xylenes (BTEX) and other volatile organic compounds (VOCs) in water, air, and soil.

The FROG-4000TM miniaturizes components used for analytical chemistry. The system incorporates a micro preconcentrator that is coated with a designer nanoporous material. The micro preconcentrator has an integrated heater for thermal desorption. Defiant’s micro GC separates target analytes in less than 5 minutes. The micro GC column also has an integrated heater for temperature ramp chromatography. Ramping the temperature reduces the analysis time and aids in the separation of late eluting compounds. The detector is a miniature PID (10.6 eV). Chemical name and concentration can be viewed on FROG-4000’s LCD display, or the user may watch the chromatogram real time on a computer.  FROG-4000TM includes a micro-SD card to store results from the field. Data can be downloaded from the SD card for further analysis at a later time.

 

show more

Inficon DataFID Portable Flame Ionization Detector for Leak Detection and Repair (LDAR)
Inficon DataFID Portable Flame Ionization Detector for Leak Detection and Repair (LDAR)

LDAR programs have been implemented to identify unintended volatile organic compound (VOC) leaks in various components used in refinery and industrial processes. LDAR programs consist of specified monitoring requirements for both frequency of testing and the level of emissions from a given component type, such as a valve, connector or pump.  US EPA Method 21 outlines the protocol to be followed when conducting LDAR operations, and intrinsically safe flame ionization detection (FID) technology is specified in Method 21 for VOC leak detection.

DataFID is a portable, intrinsically safe flame ionization detector that can reliably measure VOCs in a potentially hazardous environment. DataFID has built in Bluetooth® wireless technology for fast data download to a handheld datalogging PDA.  An external Bluetoothantenna is installed to boost wireless coverage and minimize signal interference.  The revolutionary Hydrostik™ metal hydride hydrogen fuel cylinder provides high purity, low pressure (80 psi) hydrogen to DataFID for continuous VOC monitoring. This conveniently-sized, lightweight refillable cylinder provides 10 hours of hydrogen supply and can easily fit in a pocket.  These features, along with its rugged chassis and long battery life, make DataFID the ideal instrument for Leak Detection and Repair operations in a refinery or industrial process.

DataFID is designed to meet and exceed US EPA Method 21 requirements, providing reliable measurement data for LDAR operation. A Method 21 mode allows users to pre-program sampling points and leak definitions to use for specific locations, or enter the location manually after each data point has been collected. Additionally, DataFID is compatible with common LDAR software packages, including Guideware™ and LeakDAS®.

show more

Ion Science PhoCheck GasCheck 5000 IS PID
Ion Science PhoCheck GasCheck 5000 IS PID

The GasCheck 5000is is conveniently calibrated against helium- the most commontly used tracer gas - and is particularly sensitive to ammonia, argon, butane, hydrogen, SF6 and refrigerants. Leak detection is made easy thanks to the insturment's loud audible alarm and flashing LED, leaving the user in no doubt that a leak has been detected. The adavanced leak detector with download capability for easy data analysis.

show more

Photovac DataFID
Photovac DataFID

The DataFID represents the newest generation in flame ionization technology with integral Bluetooth wireless technology for fast data download to a portable datalogging PDA or office computer. Now, cumbersome add-on communication attachments can be eliminated with the DataFID’s wireless technology.

show more

Photovac MicroFID IS Flame-Ionization Detector
Photovac MicroFID IS Flame-Ionization Detector

Flame Ionization Detector (FID) now available to hire from Pine. A small and lightweight FID (Flame Ionization Detector) with built-in datalogging, the Photovac MicroFID allows trouble-free measurement of soil gases when the response-factor consistency of a FID is mandatory, or when methane must be included in the total reading. The MicroFID is also an appropriate instrument for leak testing, remediation efficiency checks and emergency spill response. UHP hydrogen fuel is available for purchase. Please contact our local office for a quotation for hire/ rental rates.

show more

RAE Systems MiniRAE 2000 PID
RAE Systems MiniRAE 2000 PID

The RAE Systems MiniRAE 2000 PID photoionization detector (PID) is now available to hire from Pine. Having a 10.6eV lamp that weighs just over a pound, yet it’s a heavyweight for lead detection, fugitive emissions monitoring to EPA Method 21. The MiniRAE 2000 portable VOC monitor is also a highly useful tool in industrial hygiene and environmental applications, including indoor air quality series.

A list of the gases detectable by this instrument are available to download in the TN-106 PDF document under the Download tab.

show more

RAE Systems MiniRAE 3000 PID
RAE Systems MiniRAE 3000 PID

The MiniRAE 3000 PID is the most advanced handheld volatile organic compound (VOC) detector on the market. Its Photoionization Detector’s (PID) extended range of 0 to 15,000 ppm makes it an ideal instrument for applications from industrial hygiene, to leak and hazmat detection.

The RF modem allows real-time data transmissions with a base controller located up to 500 feet (or two-miles with optional RAELink2 portable modem) away from the MiniRAE 3000 detector.

A personal computer can be used as the base station for a Mini-RAE 3000 system. The standard ProRAE Remote software is capable of monitoring the input of up to 64 remotely-located monitors like MiniRAE 3000, or AreaRAE, etc.

A list of the gases detectable by this instrument are available to download in the TN-106 PDF document under the Download tab.

show more

RAE Systems MiniRAE Lite PID
RAE Systems MiniRAE Lite PID

Ideal for simpler VOC detection and monitoring applications, the new MiniRAE Lite from RAE Systems is now available to hire, buy or through our Rent To Own (RTO) and Perpetual Rental Plan (PRP).

Featuring the same lamp as the MiniRAE 3000 and a powerful pump able to draw up to 30m, the MiniRAE Lite is simple to use and robust. Potential applications vary from in-house solvent monitoring and environmental site surveys to construction and Spill Response.

show more

RAE Systems Multi PID 4-Gas Monitor with PID
RAE Systems Multi PID 4-Gas Monitor with PID

For PID Rental, the MultiRAE PID and 4 Gas monitor combines a photoionization detector with a sensitive gas detector for LEL, H2S, CO and O2. Providing confined space protection, the MultiRAE measures volatile organic compounds (VOC's) in low parts per million, including benzene, butadiene, trichloroethylene and vinyl chloride. This combined PID detector available to hire is perfect for short or long term applications, contact Pine for more details.

show more

RAE Systems ppbRAE 2000 PID
RAE Systems ppbRAE 2000 PID

The RAE Systems ppbRAE 2000 is the most sensitive handheld VOC monitor available to rent from Pine. With true parts per billion detection of extremely low level, low vapor pressure and highly toxic volatile organic compounds (VOCs), like nerve agents, pesticide residues and isocyanates. This instrument tackles applications far beyond the scope of typical PIDs such as measurements of outgassing from carpets and fabrics, spot checks for ethylene oxide and personal monitoring of heat exchange fluids, including therminol in petrochemical plants. It is also an excellent tool for indoor air quality studies. The ppbRAE is very flexible, offering user-selectable survey or hygiene modes and a user-set threshold for the 90 dB alarm. The user can also program the unit for average, STEL and peak readings. The large keys are easy to operate, even through three layers of gloves.

show more

RAE Systems ppbRAE 3000 PID
RAE Systems ppbRAE 3000 PID

The RAE ppbRAE 3000 is the most advanced handheld volatile organic compound (VOC) monitor on the market. Its photoionization detector’s (PID) extended range of 1 ppb to 10,000 ppm makes it an ideal instrument for applications from HazMat/Homeland Security and industrial hygiene to Indoor Air Quality and military applications.

show more

RAE Systems UltraRAE 3000
RAE Systems UltraRAE 3000

The UltraRAE 3000 is the most advanced Compound-Specific Monitor on the market. Its Photoionization Detector’s (PID) extended range of 0.05 to 10,000 ppm in VOC mode and 50 ppb to 200 ppm in benzene-specific mode makes it an ideal instrument for applications from entry pre-screening during refinery and plant maintenance to hazardous material response, marine spill response and refinery down-stream monitoring.

show more

RAE Systems UltraRAE Benzene Monitor Model PGM-7200
RAE Systems UltraRAE Benzene Monitor Model PGM-7200

The UltraRAE is a quick, spot-check monitor used to provide highly specific measurements of Benzene. The combination of a singe-use filter tube and PID makes this a highly accurate compound specific instrument. Applications include tank entry pre-screening during refinery and plant maintenance, hazardous material response and refinery downstream monitoring. The internal pump permits sampling up to 30 feet in a confined space. Additional Benzene filter tubes for the UltraRAE rental unit are a purchase item.

show more

ThermoFisher Scientific NEW TVA2020 with GPS and BlueTooth Connectivity
ThermoFisher Scientific NEW TVA2020 with GPS and BlueTooth Connectivity

Easy-to-Own and Operate

The TVA2020 Analyzer is 21% lighter than earlier models and more compact than most FID stand alone instruments. The lightweight and compact design reduces fatigue for true portability and is easier to service in the field. In addition, a variety of options are available such as a basic or enhanced probe, carrying case, and hydrogen refill assembly.

Optional Bluetooth communication transmits concentration data to a handheld device containing the LDAR software database thereby eliminating the need to transfer files post-monitoring and provide a greater access to route information.

The Technology You Expect

Configurable for use in diverse applications including U.S. EPA Method 21 monitoring, site remediation, landfill monitoring, and general area surveys, the TVA2020 Analyzer is equipped with an FID to measure organic compounds with high sensitivity. The FID technology allows for a wide dynamic and linear range that produces stable and repeatable responses. The analyzer can be configured with both FID and PID technology for simultaneous detection and enhanced analytical capabilities. This dual configuration is capable of producing a more rapid reading of organic and inorganic compounds as opposed to a single detector technology and provides more comprehesive gas coverage than comparable size devices.

After performing a primary calibration, the TVA2020 Analyzer can be customized by activating internal logging parameters, uploading a monitoring route, establishing a bluetooth connection, setting alarm levels, and activating response factors.

show more