Horiba U-52, Multiparameter Water Quality Checker
Home »
Products »
Water Monitoring »
Multi-Parameter with Flow Cell »
Horiba U-52
Product Overview
The Horiba U-52 Multi-parameter water quality checker enables a user to measure up to 11 parameters simultaneously with just one unit. Tough and powerful design, and a consideration for user friendly field monitoring of river, ground water, drainage water, and more, brings together both function and performance, which allows a simple operation for every user.
Product Features:
High sensitivity turbidity sensor incorporated.
A membrane cap for stress free maintenance of the dissolved oxygen sensor.
A hand-held transmitter and sensor probe – designed for easy one-handed operation and data confirmation.
One touch calibration makes routine calibrations for pH, DO, conductivity, turbidity and water depth a breeze.
Product Specifications
Sensor Probe
Max.items displaying simultaneously
11
Measurement temperature
-5 to 55°C
Max. sensor diameter
Approx. 96 mm
Probe length
Approx. 340 mm
Cable length
Standard: 2 m, Option: 10, 30 m
Mass
Approx. 1800 g
Automatic calibration (use pH4 )
Applying to all models
Measurement depth
Max. 30 m
Material contact with liquid
PPS, glass, SUS316L, SUS304, FKM, PEEK, Titaniumu, FEP membrane, POM
Water resistance
JIS protection level 8
Monitor
Outer dimensions
115(W) X 65(D) X 280(H) mm
Mass
Approx. 800 g
LCD
320 X 240 Graphic liquid crystal with backlight (black and white)
Data memory
10000
Communication
USB peripheral
Battery
C batteries X 4
Water resistance
JIS protection level 7 (when sensor cable is fitted)
Battery life
Approx. 70 hours (without backlight)
Storage temperature
-10 to 60°C
Ambient temperature
-5 to 45°C
pH
Two point calibration
yes
Automatic temperature
yes
Measurement principle
Glass electrode method
Range
pH 0 to 14
Resolution
0.01pH
Repeatability
±0.05pH
Accuracy
±0.1pH
Dissolved Oxygen (DO)
Salinity conversion
0 to 70 PPT / automatic
Automatic temperature compensation
yes
Measurement principle
Polarograph method
Range
0 to 50.0 mg/L
Resolution
0.01 mg/L
Repeatability
±0.1 mg/L
Accuracy
0 to 20 mg/L: ±0.2 mg/L, 20 to 50 mg/L: ±0.5 mg/L
Conductivity (COND)
Auto range
yes
Automatic temperature compensation
25°C
Measurement principle
4 AC electrode method
Range
0 to 10 S/m (0 to 100 mS/cm)
Resolution
0.000 to 0.999 mS/cm: 0.001
1.00 to 9.99 mD/cm: 0.01
10.0 to 99.9 mS/cm: 0.1
0.0 to 99.9 mS/m: 0.1
0.100 to 0.999 S/m: 0.001
1.00 to 9.99 S/m: 0.01
Repeatability
±0.05% F.S.
Accuracy
±1% F.S. (Median of two-point calibration)
Salinity
Measurement principle
Conductivity conversion
Range
0 to 70 PPT (permillage)
Resolution
0.1 PPt
Repeatability
±1 PPT
Accuracy
±3 PPT
Total Dissolved Solid (TDS)
Conversion factor setting
yes
Measurement principle
Conductivity conversion
Range
0 to 100 g/L
Resolution
0.1 F.S.
Repeatability
±2 g/L
Accuracy
±5 g/L
Seawater specific gravity
Display
d1, d0, d15
Measurement principle
Conductivity conversion
Range
0 to 50 dt
Resolution
0.1 dt
Repeatability
±2 dt
Accuracy
±5 dt
Temperature
Measurement principle
Thermistor method
Range
-5 to 55°C
Resolution
0.01°C
Repeatability
±0.10°C (at calibration point)
Accuracy
JIS class B platinum thermometer sensor (±0.3+0.005)
Turbidity (TURB)
Measurement principle
30°LED forward penetration and scattering method
Range
0 to 800 NTU
Resolution
0.1 NTU
Repeatability
±5% (reading) or ±0.5 NTU whichever is greater
Accuracy
±5% (reading) or ±1 NTU whichever is greater
Oxidation Reduction Potential (ORP)
Measurement principle
Platinum electrode method
Range
-2000 mV to +2000 mV
Resolution
1 mV
Repeatability
±5 mV
Accuracy
±15 mV
Other products in this category: